{"id":39,"date":"2016-07-13T14:56:01","date_gmt":"2016-07-13T12:56:01","guid":{"rendered":"http:\/\/www.axilumrobotics.com\/ww2\/en\/?page_id=39"},"modified":"2022-01-24T16:47:26","modified_gmt":"2022-01-24T15:47:26","slug":"tms-robot-features","status":"publish","type":"page","link":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/","title":{"rendered":"TMS-Robot Features"},"content":{"rendered":"<div id=\"image_volet\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-44 aligncenter\" src=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg\" alt=\"accueil_light\" width=\"642\" height=\"277\" \/><br \/>\n<i>Example of a typical setup with Axilum Robotics TMS-Robot<\/i><\/div>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify\"><b>Axilum Robotics TMS-Robot<\/b> is the first robot developed specifically to assist researchers and health care professionals for the positioning of a Transcranial Magnetic Stimulation coil. It includes a 7 degree-of-freedom robotic arm and a 2 degree-of-freedom, computer-controlled patient seat.<\/p>\n<p style=\"text-align: justify\">Axilum Robotics TMS-Robot, in combination with a <a href=\"https:\/\/www.axilumrobotics.com\/en\/build-your-robotic-tms-system\/\">compatible neuronavigation system<\/a> and a <a href=\"https:\/\/www.axilumrobotics.com\/en\/build-your-robotic-tms-system\/\">compatible coil<\/a> connected to its own stimulator, allows the automatic execution of an image guided <a href=\"https:\/\/www.axilumrobotics.com\/en\/the-three-steps-to-perform-a-tms-session-with-axilum-robotics-tms-robot\/\">TMS session<\/a> planned in advance. Once the stimulation targets and coil self-rotation have been defined in the neuronavigation system, Axilum Robotics TMS-Robot positions the coil tangentially at these targets, ensures contact between coil and head, and compensates for any head movements during the session, keeping the coil position and orientation with respect to the brain.<\/p>\n<h1 style=\"text-align: justify\">Key Features<\/h1>\n<p style=\"text-align: justify\"><b>Large Workspace<\/b><\/p>\n<p style=\"text-align: justify\">The original, patented, hemispherical architecture of the robotic arm allows the positioning of the coil&#8217;s stimulation hot spot around a hemisphere. This architecture enables access to all stimulation areas while the head is located inside the work hemisphere. The computer-controlled patient seat facilitates the adjustment of the patient head inside the workspace.<\/p>\n<p style=\"text-align: justify\"><b>Accuracy and Repeatability<\/b><\/p>\n<p style=\"text-align: justify\">Axilum Robotics TMS-Robot offers improved accuracy. The robotic arm and the patient seat include 9 high-precision position sensors that allow to measure and repeat any desired configuration of the coil with respect to the brain.<\/p>\n<p style=\"text-align: justify\"><b>Coil Orientation Control<\/b><\/p>\n<table style=\"width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 50%\">\n<p style=\"text-align: justify\">The hemispherical architecture of the robotic arm allows to:<\/p>\n<ul style=\"text-align: justify\">\n<li style=\"list-style-type: none\">\n<ul style=\"text-align: justify\">\n<li>Orientate the coil when applied on the head surface to reach the desired internal structures.<\/li>\n<li>Control the self-rotation of the coil to define the direction of the induced electric field.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>This provides a way to control precisely the stimulation entry point and the stimulated internal structures.<\/td>\n<td style=\"width: 50%\" align=\"left\"><a title=\"Exemple de LOCALITE TMS Navigator avec le module Axilum Robotics\" href=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/captureLocalite.png\" target=\"_blank\" rel=\"noopener noreferrer\"> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-45\" src=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/captureLocalite_small.png\" alt=\"captureLocalite_small\" width=\"300\" height=\"168\" \/><br \/>\n<small><i>Click on the picture to enlarge it<\/i><\/small> <\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Head Motion Compensation<\/b><\/p>\n<p style=\"text-align: justify\">The neuronavigation system monitors the coil position and orientation in real time to compensate for any movement of the head measured by its 3D optical tracking system during the stimulation.<\/p>\n<p><b>Contact Detection and Control<\/b><\/p>\n<p style=\"text-align: justify\">A flat force sensor that is non-sensitive to the magnetic field is affixed on the inferior surface of the TMS coil to measure the contact between the coil and the head. The robot&#8217;s embedded software controls the applied force in real time so that it does not exceed the coil&#8217;s own weight. Therefore, stimulations can be delivered only when the coil is touching the head.<\/p>\n<p><b>Safety<\/b><\/p>\n<p style=\"text-align: justify\">The patient head is located in the center of the work hemisphere by means of the computer-controlled seat. Each joint of the robot arm is equipped with mechanical hard stops to limit their movement amplitude. Thanks to the hemispherical architecture of the arm, the coil cannot draw a straight line when moving from one side of the head to another, but only move around that hemisphere. This prevents the coil or the robotic arm to hit the patient&#8217;s head during coil positioning. Moreover, the robot&#8217;s embedded software limits the force applied by the coil on the head in real time for a safe and comfortable session.<\/p>\n<p><b>Ergonomy<\/b><\/p>\n<table style=\"width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 50%\" align=\"right\"><a title=\"Exemple de Brainsight TMS Navigation avec le module Axilum Robotics\" href=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/captureBrainsight.png\" target=\"_blank\" rel=\"noopener noreferrer\"> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-48\" src=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/captureBrainsight_small.png\" alt=\"captureBrainsight_small\" width=\"300\" height=\"168\" \/><br \/>\n<small><i>Click on the image to enlarge it<\/i><\/small> <\/a><\/td>\n<td style=\"width: 50%\">\n<p style=\"text-align: justify\">Axilum Robotics TMS-Robot does not add a separate user interface. The operator can control the robot and define the desired movements and positions of the coil from the graphical user interface of a compatible neuronavigation system. The robot contains its own power supply unit, which is included in the hardware structure. The computer-controlled patient seat is reclinable and its height and depth can be set by a compatible neuronavigation system to adapt to the patient&#8217;s morphology.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Dimensions and Weight<\/b><\/p>\n<p style=\"text-align: justify\">Axilum Robotics TMS-Robot fits to any space and enters into most elevators thanks to its practical dimensions and reasonable weight. It can be moved easily on its integrated wheels.<\/p>\n<ul>\n<li>Minimum height: 1950 mm<\/li>\n<li>Base dimensions: 1523 x 769 mm<\/li>\n<li>Weight: 400 kg<\/li>\n<\/ul>\n<h1>Additional Ressources<\/h1>\n<p style=\"text-align: justify\">You can get additional information from ressources below.<\/p>\n<p style=\"text-align: justify\">Learn the <a href=\"https:\/\/www.axilumrobotics.com\/en\/the-three-steps-to-perform-a-tms-session-with-axilum-robotics-tms-robot\/\">three steps<\/a> to perform a TMS session with Axilum Robotics TMS-Robot.<br \/>\nCheck the <a href=\"https:\/\/www.axilumrobotics.com\/en\/build-your-robotic-tms-system\/\">compatibility<\/a> of Axilum Robotics TMS-Robot with existing neuronavigation systems, TMS coils and stimulators, and EEG measurement devices.<br \/>\nCheck important <a href=\"https:\/\/www.axilumrobotics.com\/en\/regulatory-information\/\">regulatory<\/a> information of Axilum Robotics TMS-Robot for your country of residence.<\/p>\n<p><a href=\"https:\/\/www.axilumrobotics.com\/publications\/\"> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-777\" src=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/logoarchives.jpg\" alt=\"logoarchives\" width=\"50\" height=\"50\" \/><\/a>\u00a0Read <a href=\"https:\/\/www.axilumrobotics.com\/en\/publications\/\">publications<\/a> of ICube about Axilum Robotics TMS-Robot.<\/p>\n<p><a href=\"https:\/\/www.axilumrobotics.com\/pdf\/Axilum_Brochure_2014_ENG_VA2016-04-02.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-28\" src=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/icone_pdf.png\" alt=\"icone_pdf\" width=\"31\" height=\"48\" \/><\/a> <a href=\"https:\/\/www.axilumrobotics.com\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">Request<\/a> our promotional brochure presenting Axilum Robotics TMS-Robot.<\/p>\n<p><a href=\"https:\/\/www.axilumrobotics.com\/videos-de-demonstration-de-tms-robot\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-779\" src=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/youtube-logo.jpg\" alt=\"youtube-logo\" width=\"82\" height=\"58\" \/><\/a>\u00a0<a href=\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-demo-videos\/\">Watch demos videos<\/a> of Axilum Robotics TMS-Robot.<\/p>\n<p style=\"text-align: justify\"><i>This page provides non contractual information; All specifications are subject to change without prior notice.<\/i><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Example of a typical setup with Axilum Robotics TMS-Robot &nbsp; Axilum Robotics TMS-Robot is the first robot developed specifically to assist researchers and health care professionals for the positioning of a Transcranial Magnetic Stimulation coil. It includes a 7 degree-of-freedom robotic arm and a 2 degree-of-freedom, computer-controlled patient seat. Axilum Robotics TMS-Robot, in combination with&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_trash_the_other_posts":false,"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"editor_notices":[],"footnotes":""},"class_list":["post-39","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>A robot to assist in transcranial magnetic stimulation (TMS \/ rTMS) - Healthcare Professionals - Axilum Robotics [EN]<\/title>\n<meta name=\"description\" content=\"Main features of a robotic assistant for transcranial magnetic stimulation: accuracy, repeatability, movement compensation, coil orientation control...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A robot to assist in transcranial magnetic stimulation (TMS \/ rTMS) - Healthcare Professionals - Axilum Robotics [EN]\" \/>\n<meta property=\"og:description\" content=\"Main features of a robotic assistant for transcranial magnetic stimulation: accuracy, repeatability, movement compensation, coil orientation control...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/\" \/>\n<meta property=\"og:site_name\" content=\"Axilum Robotics [EN]\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/axilumrobotics\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-24T15:47:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@axilumrobotics\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/\",\"url\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/\",\"name\":\"A robot to assist in transcranial magnetic stimulation (TMS \/ rTMS) - Healthcare Professionals - Axilum Robotics [EN]\",\"isPartOf\":{\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg\",\"datePublished\":\"2016-07-13T12:56:01+00:00\",\"dateModified\":\"2022-01-24T15:47:26+00:00\",\"description\":\"Main features of a robotic assistant for transcranial magnetic stimulation: accuracy, repeatability, movement compensation, coil orientation control...\",\"breadcrumb\":{\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#primaryimage\",\"url\":\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg\",\"contentUrl\":\"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.axilumrobotics.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TMS-Robot Features\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.axilumrobotics.com\/en\/#website\",\"url\":\"https:\/\/www.axilumrobotics.com\/en\/\",\"name\":\"Axilum Robotics [EN]\",\"description\":\"Robot for transcranial magnetic stimulation (TMS and rTMS)\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.axilumrobotics.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A robot to assist in transcranial magnetic stimulation (TMS \/ rTMS) - Healthcare Professionals - Axilum Robotics [EN]","description":"Main features of a robotic assistant for transcranial magnetic stimulation: accuracy, repeatability, movement compensation, coil orientation control...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/","og_locale":"en_US","og_type":"article","og_title":"A robot to assist in transcranial magnetic stimulation (TMS \/ rTMS) - Healthcare Professionals - Axilum Robotics [EN]","og_description":"Main features of a robotic assistant for transcranial magnetic stimulation: accuracy, repeatability, movement compensation, coil orientation control...","og_url":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/","og_site_name":"Axilum Robotics [EN]","article_publisher":"http:\/\/www.facebook.com\/axilumrobotics","article_modified_time":"2022-01-24T15:47:26+00:00","og_image":[{"url":"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@axilumrobotics","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/","url":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/","name":"A robot to assist in transcranial magnetic stimulation (TMS \/ rTMS) - Healthcare Professionals - Axilum Robotics [EN]","isPartOf":{"@id":"https:\/\/www.axilumrobotics.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#primaryimage"},"image":{"@id":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#primaryimage"},"thumbnailUrl":"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg","datePublished":"2016-07-13T12:56:01+00:00","dateModified":"2022-01-24T15:47:26+00:00","description":"Main features of a robotic assistant for transcranial magnetic stimulation: accuracy, repeatability, movement compensation, coil orientation control...","breadcrumb":{"@id":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#primaryimage","url":"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg","contentUrl":"https:\/\/www.axilumrobotics.com\/wp-content\/uploads\/2016\/07\/accueil_light.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.axilumrobotics.com\/en\/tms-robot-features\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.axilumrobotics.com\/en\/"},{"@type":"ListItem","position":2,"name":"TMS-Robot Features"}]},{"@type":"WebSite","@id":"https:\/\/www.axilumrobotics.com\/en\/#website","url":"https:\/\/www.axilumrobotics.com\/en\/","name":"Axilum Robotics [EN]","description":"Robot for transcranial magnetic stimulation (TMS and rTMS)","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.axilumrobotics.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/pages\/39","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/comments?post=39"}],"version-history":[{"count":15,"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/pages\/39\/revisions"}],"predecessor-version":[{"id":1256,"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/pages\/39\/revisions\/1256"}],"wp:attachment":[{"href":"https:\/\/www.axilumrobotics.com\/en\/wp-json\/wp\/v2\/media?parent=39"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}